:: Manufacturer Partners:: Featured Products
|
Temperature Transmitters
|
Accutech |
AI-1500 |
 |
Thermocouple, RTD, Resistance & mVDC Inputs |
HART or Removable Local Display Set-up | |
Pyromation |
Series 440 |
 |
100 Ohm Platinum RTD Input |
Pyromation Software for Set-up | |
Pyromation |
Series 442 |
 |
Thermocouple, RTD, Resistance & mVDC Inputs |
HART for Set-up | |
Level Transmitters
Ametek |
575 |
 |
Submersible Hydrostatic Pressure with Snub Nose |
Water & Liquids |
2-Wire 4-20 mADC Output | |
Ametek |
575 P |
 |
Submersible Hydrostatic Pressure with Protected Flush Diaphragm |
Waste Water & Slurry |
2-Wire 4-20 mADC Output | |
Dwyer |
CLT |
 |
Tank Top Mounting with Float on Brass or SS Stem |
Liquids |
4-20 mADC or 0 to (10-30) VDC | |
STI |
LPU-2127 |
 |
Loop Powered Ultrasonic Level Sensor |
Liquids & Solids |
2-Wire 4-20 mADC & Local Display | |
Bindicator |
Cap-Level II A |
 |
Radio Frequency Capacitance Using Rigid or Cable Probe |
Liquids
|
2-Wire 4-20 mADC Output | |
Bindicator |
GP 4 & Mark 4 Yo-Yo |
 |
Tank Top Unit with Weight & Retractable Cable |
Solids, Liquids & Liquid / Solid Interface |
4-20 mADC, RS-485(MODBUS) & Local Readout | |
Bindicator |
Phase Tracker |
 |
Tank Top Unit with Cable using Phase Difference Technology |
Solids & Liquids -Ignores Dust, Vapors & Foam |
4-20 mADC, RS-232, Modem, Relay & Local Readout | |
Bindicator |
SonoTracker |
 |
Tank Top Mounting Using Ultrasonic Technology |
Solids & Liquid Level, Open Channel Flow and Differential Level |
4-20 mADC, RS-485, Allen Bradley RIO, Profibus & Local Readout | |
Flow Transmitters
|
Barksdale |
UQS7
|
 |
Ultrasonic |
0.1 to 45 GPM Water-based Liquids
|
3/4" to 1 1/4" Pipe |
250:1 Turndown
|
+/- 2.5% of Full Scale Accuracy
| |
Bindicator |
SonoTracker
|
 |
Ultrasonic |
Open Channel Flow with Weir or Flume
|
2" to 100" Depth |
10:1 Turndown
|
+/- 1% of Rate Accuracy
| |
Kobold |
DMI PMG
|
 |
Magetic Inductive |
DMI: 0.7 to 320 GPM PMG: 0.2 to 10,000 GPM Liquids & Slurries |
3/8" to 12" Pipe |
12:1 to 30:1 Turndown Depending on Line Size |
DMI: +/- 1.5% or 3% of Rate Accuracy PMG: +/- 0.25% or 0.5% of Rate Accuracy | |
Dwyer |
Series 641 Air Velocity |
 |
Heated Mass Flow Sensor |
Up to 15,000 FPM Air
|
6" to 36" Insertion Probe |
-40 to +212ºF |
100 PSIG Maximum |
+/-3% (32 to 122ºF) or 4% of Full Scale Accuracy | |
Dwyer |
Series AVU Air Velocity |
 |
Heat Loss Sensing Element |
Up to 3,150 FPM Air
|
9" Insertion Probe |
32 to +122ºF |
2 PSIG Maximum |
+/-5% of Full Scale Accuracy
| |
Dwyer |
Series PF & PFS Air Velocity |
 |
Heated Mass Flow Sensor |
PF: Up to 6,000 SFPM Air PFS: Up to 15,000 SFPM Air |
13" Insertion Probe |
-40 to +250ºF |
150 PSIG Maximum |
+/-1% of Full Scale Accuracy
| |
Weber |
Type 3205 vent-captor |
 |
Calorimetric principle |
Up to 3,800 FPM Air
|
2" Insertion Probe |
-4 to +160ºF |
145 PSIG Maximum |
+/-5% of Full Scale Accuracy
| |
Weber |
Type 3302 vent-captor
|
 |
Calorimetric principle |
Up to 3800 FPM Air |
8, 12, 18, 22 & 28 mm tubing |
-4 to +160ºF |
145 PSIG Maximum |
+/-5% of Full Scale Accuracy | |
|
Weber |
Types 4114 30 & 4115 30 flow-captor |
 |
Calorimetric principle |
Up to 6.5 FPS - Liquids |
2.14" or 2.4" Insertion Probe |
14 to +176ºF |
435 PSIG Maximum |
+/-5% of Full Scale Accuracy | |
Weber |
Type 4311 30 flow-captor
|
 |
Calorimetric principle |
Up to 3.3 FPS - Liquids |
8, 12, 18, 22 & 28 mm tubing |
14 to +176ºF |
435 PSIG Maximum |
+/-5% of Full Scale Accuracy | |
Humidity and Oxygen Transmitters
EdgeTech |
H-S Relative Humidity Transmitter |
 |
Range: 10 to 95% RH (Operating: 40 to 160ºF) |
Accuracy: +/- 3% RH (30 to 80% RH)
|
Output: 0-10 VDC = %RH
|
Wall, Duct or Outside Air Mounting | |
EdgeTech |
600 Relative Humidity & Temperature Transmitter |
 |
Ranges: 0 to 100% RH -4 to +248ºF |
Accuracies +/- 2% RH (0 to 90% RH) +/-0.6ºF (-4 to +122ºF) |
Output(s): 4-20 mADC = %RH & Temperature
|
Wall, Duct or Remote Mounting | |
EdgeTech |
650 Precision Relative Humidity & Temperature Transmitter |
 |
Ranges: 0 to 100% RH -40 to +356ºF |
Accuracies +/- 1% RH (10 to 90% RH) +/-0.36ºF (-4 to +140ºF) |
Output(s): 4-20 mADC = %RH, Dew Point or g/k plus Temperature |
Wall, Duct or Remote Mounting | |
EdgeTech |
WBL-200 Wireless Relative Humidity & Temperature Data Logger |
 |
Ranges: 0 to 100% RH -67 to +266ºF |
Accuracies +/- 2% RH (11 to 55% RH) +/-1.8ºF @ 77ºF |
20,000 Data Points On Board Data Logging. RS 232 & USB for Real Time Recording |
Surface Mounting Enclosure | |
EdgeTech |
HTPB Series Multi-Parameter Humidity & Temperature Probes |
 |
Ranges: 5 to 95% RH -4 to +240ºF Temperature -76 to +203ºF Dew Point 0-200 PSIA Pressure |
Accuracy +/- 1% RH (5 to 95% RH)
|
Outputs: RS 232 plus Three (3) 0-10 VDC = Selectable %RH, Dew Point, ppmv, ppmw, gr/lb, g/kg, Temperature or Pressure |
Wall, Duct, 3/4" Compression Fitting or Remote Mounting | |
EdgeTech |
6740 Series Humidity Transmitter in Compressed Air |
 |
Range: -76 to +86ºF Dew Point (Operating: 30" Hg Vacuum to 0 to 725 PSIG Pressure) |
Accuracy +/- 3.6ºF @ 23ºF Dew Point
|
Outputs: 4-20 mADC = Selectable Dew Point or ppmv plus 2 optional alarms
|
1/2" NPT Process Connection | |
EdgeTech |
Model 200 DewTrak Chilled Mirror Dew Point Transmitter |
 |
Range: -40 to +140ºF Dew Point (Operating: -40 to +162ºF Temperature; 1,000 PSIG Maximum Pressure) |
Accuracy +/- 1ºF Dew Point
|
Outputs: 4-20 mADC = Dew Point, %RH, Wet Bulb or Grains per Pound;Optional Temperature
|
Wall, Duct, 1 1/4" NPT or Aspirator Mounting | |
EdgeTech |
OxyTrans Oxygen Transmitter |
 |
Oxygen Ranges: 0-100, 0-1,000 or 0-10,000 PPM 0-1 or 0-25% (Operating: -40 to +162ºF)
|
Accuracy: +/- 2% FSD at Constant Temperature +/- 5% FSD from 32 to 122ºF |
Outputs: 4-20 mADC, Alarm & Local Display
|
Compression Fittings with Flow-Through Measuring Cell | |
|
|