Pressure Calibrators
Pressure Calibrators | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Digital Electronic Calibrators | ||||||||||
Manufacturer | Series | Range of Integral Pressure Sensor | Pressure Accuracy. NIST Traceable | mA Reading | 24 VDC Transmitter Supply | Switch Test | External Pressure Module Capability | Additional Inputs / Outputs | Serial Interface | |
Ametek Jofra | DPC-500 | "+/-0.025% of Full Scale | X | X | X | Vacuum, "H2O, Absolute, up to 14,500 PSIG | VDC | DPC-Cal Documenting Software. USB & RS232 | ||
Ametek Jofra | ASC300 | "+/-0.01% F.S. and +/-0.05% F.S. | X | X | X | Vacuum, "H2O, Absolute, Differential, up to 10,000 PSIG | RTD, Thermocouple, Voltage, Frequency, Pulse Train, Resistance | JOFRACAL Calibration Software. RS232 | ||
Ametek Jofra | APC | Vacuum to 10,000 PSIG | "+/- 0.04% of Reading +/- 0.01% F.S. | X | X | X | Vacuum, "H2O, Absolute, Differential, up to 10,000 PSIG | ASCII RS232 | ||
Ametek Jofra | CPC | Vacuum to 200 PSIG | "+/-0.05% of Full Scale | X | X | |||||
Ametek Jofra | IPI | Vacuum to 10,000 PSIG | "+/-0.05% of Full Scale | ASCII RS232 |
Dead Weight Testers | |||||||
---|---|---|---|---|---|---|---|
Manufacturer | Model | Media | Range | Increments | NIST Traceable Accuracy of Reading | Options | |
Ametek M&G | T Tester | Water/Alcohol or Hydraulic Fluids | 10 to 15,000 PSIG | 5, 10, 25 or 50 PSIG depending on range | Standard: +/-0.100% Optional: +/-0.025%; +/-0.015% | Dual Pistons; Dual Columns | |
Ametek M&G | HL | AAA Tester Oil | 10 to 3,000 PSIG | 0.10 or 0.50 PSIG depending on range | Standard: +/-0.100% Optional: +/-0.05% | ||
Ametek M&G | RK | Pneumatic | 4 to 1614" H2O 1 to 300 PSIG | Standard: 1" H2O; 1 PSIG Optional: 0.1" H2O; 0.1 PSIG | Standard: +/-0.050% Optional: +/-0.025%; +/-0.015% | ||
Ametek M&G | PK II | Pneumatic | 4 to 850" H2O 1 to 30 PSIG | 1" or 10" H2O; 1 PSIG depending on range | Standard: +/-0.050% Optional: +/-0.025%; +/-0.015% | ||
Ametek M&G | HK | Pneumatic | 10 to 1500 PSIG | 1 PSIG | Greater of +/-0.025 PSIG or +/-0.025% of Reading |
Pressure & Vacuum Pumps | ||||||||
---|---|---|---|---|---|---|---|---|
Manufacturer | Model | Media | Range | Pumping Style | Size | Connections | Other Features | |
Ametek M&G | T Pump | Water/Alcohol or Hydraulic Fluids | 0 to 15,000 PSIG | Dual Volume Lever Handle | Bench Mount | BSP & NPT Manifold | Seals: Buna N, EPT, Viton | |
Ametek Jofra | P014 | Hydraulic Oil | 0 to 10,000 PSIG | Lever Handle | Portable Bench Mount | BSP Manifold | ||
Ametek Jofra | P016 P017 | Hydraulic Oil | 0 to 5,000 PSIG | Screw | Portable Bench Mount | BSP Manifold | ||
Ametek M&G | T-620 | Hydraulic Oil | 0 to 5,000 PSIG | Pistol Grip | Hand Held | BSP & NPT Body & Hose | ||
East Hills | MVP 600 | Pneumatic | Vacuum to 600 PSIG | Molded Cushion Scissors Handle | Hand Held | BSP Body | Schrader Valve. Optional NPT Fittings & Hose | |
Ametek M&G | T-930 | Pneumatic | 28" Hg Vacuum to 500 PSIG | Scissors Handle | Hand Held | BSP & NPT Body & Hose | ||
Ametek M&G | T-730 T-740 T-750 | Pneumatic | 30 PSIG 200 PSIG 25" Hg Vacuum | Pistol Grip | Hand Held | BSP & NPT Body & Hose |
Temperature Calibrators | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Ametek | Jofra | ||||||||||
Model (Includes JOFRACAL Software) | Range @ 73°F Ambient Temperature | Stability | Accuracy. External STS Reference Sensor | Accuracy: Standard with Internal Reference Sensor | Immersion Depth | Insertion Tube Diameter | Automatic Switch Test | Inputs: Transmitter, RTD, T/C, External Reference Probe | PC Documentation via RS232 Work Orders. As Found / As Left | Options | |
ATC-125A ATC-125B | "-130 to +257°F | "+/-0.054°F | "+/-0.11°F (Model B Only) | "+/-0.54°F | 7.3" | 1.2" | (Model B Only) | (Model B Only) | (Model B Only) | ||
ETC-125 | "-14 to +257°F | "+/-0.090°F | "+/-0.90°F | 4.3" | 0.50" | ||||||
ATC-140A ATC-140B | "-4 to +284°F | "+/-0.036°F | "+/-0.07°F (Model B Only) | "+/-0.32°F | 7.1" (Dry) 5.9" (Liquid) | 2.5" | (Model B Only) | (Model B Only) | (Model B Only) | Liquid Bath Confguration | |
CTC-140A | 1 to 284°F | "+/-0.090°F | "+/-0.70°F | 4.4" | 0.76" | X | |||||
ATC-156A ATC-156B | "-11 to +311°F | "+/-0.018°F | "+/-0.07°F (Model B Only) | "+/-0.18°F | 6.3" | 1.2" | (Model B Only) | (Model B Only) | (Model B Only) | ||
ITC-155A | "-9 to +311°F | "+/-0.050°F | "+/-0.45°F | 6.3" | 0.79" | X | |||||
ATC-157A ATC-157B | "-49 to +311°F | "+/-0.018°F | "+/-0.07°F (Model B Only) | "+/-0.23°F | 6.3" | 0.8" | (Model B Only) | (Model B Only) | (Model B Only) | ||
ATC-250A ATC-250B | 82 to 482°F | "+/-0.036°F | "+/-0.13°F (Model B Only) | "+/-0.50°F | 5.9" (Dry) 5.9"(Liquid) | 2.5" | (Model B Only) | (Model B Only) | (Model B Only) | Liquid Bath Confguration | |
ATC-320A ATC-320B | 91 to 608°F | "+/-0.018°F | "+/-0.13°F (Model B Only) | "+/-0.36°F | 5.9" | 1.2" | (Model B Only) | (Model B Only) | (Model B Only) | ||
CTC-320A CTC-320B | 91 to 608°F | "+/-0.180°F | "+/-0.90°F | 4.3" Model A 7.5" Model B | 1.0" | X | |||||
ITC-320A | 91 to 608°F | "+/-0.050°F | "+/-0.54°F | 5.91" | 1.18" | X | |||||
ETC-400A | 82 to 752°F | "+/-0.270°F | "+/-0.90°F | 4.1" | 1.50" | ||||||
ETC-SS | 82 to 752°F | "+/-0.540°F | 0.4% of Reading +/-1.80°F | 1.4" Infrared Target | |||||||
ATC-650A ATC-650B | 91 to 1202°F | "+/-0.360°F | "+/-0.20°F (Model B Only) | "+/-0.63°F | 5.9" | 1.2" | (Model B Only) | (Model B Only) | (Model B Only) | ||
CTC-650A CTC-650B | 91 to 1202°F | "+/-0.180°F Model A +/-0.090°F Model B | "+/-1.62°F Model A +/-1.08°F Model B | 4.3" Model A 7.5" Model B | 1.0" | X | |||||
ITC-650A | 91 to 1202°F | "+/-0.070°F | "+/-0.90°F | 5.91" | 1.18" | X | |||||
CTC-1200 | 572 to 2200°F | "+/-0.180°F | "+/-3.60°F | 4.3" | 1.6" | X |