Level Transmitters
Temperature Transmitters
Level Transmitters
Submersible Hydrostatic Pressure with Protected Flush Diaphragm
Waste Water & Slurry
2-Wire 4-20 mADC Output
Radio Frequency Capacitance Using Rigid or Cable Probe
Liquids
2-Wire 4-20 mADC
Output
Tank Top Unit with Weight & Retractable Cable
Solids, Liquids & Liquid / Solid Interface
4-20 mADC, RS-485(MODBUS) & Local Readout
Tank Top Unit with Cable using Phase Difference Technology
Solids & Liquids -Ignores Dust, Vapors & Foam
4-20 mADC, RS-232, Modem, Relay & Local Readout
Tank Top Mounting Using Ultrasonic Technology
Solids & Liquid Level, Open Channel Flow and Differential Level
4-20 mADC, RS-485, Allen Bradley RIO, Profibus & Local Readout
Flow Transmitters
Insertion Flow Transmitters
In-Line Flow Transmitters
Sanitary In-Line Flow Transmitters
Target Meter
0.2 to 98,000 GPM Water
1 to 2,250,000 SCFM Air
3 to 6,000,000 PPH Steam
1/2″ to 60″ Pipe
15:1 Turndown Gas & Liquids
10:1 Turndown Steam
+/- 1% of Rate Accuracy
Ultrasonic
0.1 to 45 GPM
Water-based Liquids
3/4″ to 1 1/4″ Pipe
250:1 Turndown
+/- 2.5% of Full Scale Accuracy
Ultrasonic
Open Channel Flow
with Weir or Flume
2″ to 100″ Depth
10:1 Turndown
+/- 1% of Rate Accuracy
Heated Mass Flow Sensor
Up to 15,000 FPM Air
6″ to 36″ Insertion Probe
-40 to +212ºF
100 PSIG Maximum
-40 to +212ºF
Heat Loss Sensing Element
Up to 3,150 FPM Air
9″ Insertion Probe
32 to +122ºF
2 PSIG Maximum
+/-5% of Full Scale Accuracy
Heated Mass Flow Sensor
PF: Up to 6,000 SFPM Air
PFS: Up to 15,000 SFPM Air
13″ Insertion Probe
-40 to +250ºF
150 PSIG Maximum
+/-1% of Full Scale Accuracy
Calorimetric principle
Up to 3,800 FPM Air
2″ Insertion Probe
-4 to +160ºF
145 PSIG Maximum
+/-5% of Full Scale Accuracy
Calorimetric principle
Up to 3800 FPM Air
8, 12, 18, 22 & 28 mm tubing
-4 to +160ºF
145 PSIG Maximum
+/-5% of Full Scale Accuracy
Calorimetric principle
Up to 6.5 FPS – Liquids
1.5″ to 24″ Pipe
32 to +176ºF
250 PSIG Maximum
+/-3% of Full Scale Accuracy
Calorimetric principle
Up to 6.5 FPS – Liquids
2.14″ or 2.4″ Insertion Probe
14 to +176ºF
435 PSIG Maximum
+/-5% of Full Scale Accuracy
Calorimetric principle
Up to 3.3 FPS – Liquids
8, 12, 18, 22 & 28 mm tubing
14 to +176ºF
435 PSIG Maximum
+/-5% of Full Scale Accuracy
Humidity and Oxygen Transmitters
H-S Relative
Humidity Transmitter
Range: 10 to 95% RH (Operating: 40 to 160ºF)
Accuracy: +/- 3% RH
(30 to 80% RH)
Output: 0-10
VDC = %RH
Wall, Duct or Outside Air Mounting
600 Relative Humidity & Temperature Transmitter
Ranges: 0 to 100% RH
-4 to +248ºF
Accuracies
+/- 2% RH (0 to 90% RH)
+/-0.6ºF (-4 to +122ºF)
Output(s): 4-20 mADC = %RH & Temperature
Wall, Duct or Remote Mounting
650 Precision Relative Humidity & Temperature Transmitter
Ranges: 0 to 100% RH
-40 to +356ºF
Accuracies
+/- 1% RH (10 to 90% RH)
+/-0.36ºF (-4 to +140ºF)
Output(s): 4-20 mADC = %RH,
Dew Point or g/k
plus Temperature
Wall, Duct or Remote Mounting
WBL-200 Wireless Relative Humidity & Temperature Data Logger
Ranges: 0 to 100% RH
-67 to +266ºF
Accuracies
+/- 2% RH (11 to 55% RH)
+/-1.8ºF @ 77ºF
20,000 Data Points On Board Data Logging. RS 232 & USB for Real Time Recording
Surface Mounting Enclosure
HTPB Series Multi-Parameter Humidity & Temperature Probes
Ranges: 5 to 95% RH
-4 to +240ºF Temperature
-76 to +203ºF Dew Point
0-200 PSIA Pressure
Accuracy
+/- 1% RH (5 to 95% RH)
Outputs: RS 232 plus Three (3) 0-10 VDC = Selectable %RH, Dew Point, ppmv, ppmw, gr/lb, g/kg, Temperature or Pressure
Wall, Duct, 3/4″ Compression Fitting or Remote Mounting
6740 Series Humidity Transmitter in Compressed Air
Range: -76 to +86ºF
Dew Point (Operating: 30″ Hg Vacuum to 0 to 725
PSIG Pressure)
Accuracy
+/- 3.6ºF @ 23ºF Dew Point
Outputs: 4-20 mADC = Selectable Dew Point or ppmv plus 2 optional alarms
1/2″ NPT
Process Connection
Model 200 DewTrak Chilled Mirror Dew Point Transmitter
Range: -40 to +140ºF Dew Point (Operating: -40 to +162ºF Temperature; 1,000 PSIG Maximum Pressure)
Accuracy
+/- 1ºF Dew Point
Outputs: 4-20 mADC = Dew Point, %RH, Wet Bulb or Grains per Pound;Optional Temperature
Wall, Duct, 1 1/4″ NPT or Aspirator Mounting
OxyTrans
Oxygen Transmitter
Oxygen Ranges: 0-100, 0-1,000
or 0-10,000 PPM 0-1 or 0-25% (Operating: -40 to +162ºF)
Accuracy:
+/- 2% FSD at Constant Temperature
+/- 5% FSD from 32 to 122ºF
Outputs: 4-20 mADC,
Alarm & Local Display
Compression Fittings with Flow-Through Measuring Cell