Level Transmitters

Temperature Transmitters

Accutech AI-1000 Revision 2

Thermocouple, RTD
& mVDC Inputs

Removable Local
Display Set-up

Accutech AI-1500

Thermocouple, RTD, Resistance & mVDC Inputs

HART or Removable Local Display Set-up

Pyromation Series 440

100 Ohm Platinum
RTD Input

Pyromation Software
for Set-up

Pyromation Series 442

Thermocouple, RTD, Resistance & mVDC Inputs

HART for
Set-up

Level Transmitters

Ametek 575

Submersible Hydrostatic Pressure with Snub Nose

Water & Liquids

2-Wire 4-20 mADC Output

Ametek 575 P

Submersible Hydrostatic Pressure with Protected Flush Diaphragm

Waste Water & Slurry

2-Wire 4-20 mADC Output

Dwyer CLT

Tank Top Mounting with Float on Brass or SS Stem

Liquids

4-20 mADC or 0 to (10-30) VDC

STI LPU-2127

Loop Powered Ultrasonic Level Sensor

Liquids & Solids

2-Wire 4-20 mADC & Local Display

Bindicator Cap-Level II A

Radio Frequency Capacitance Using Rigid or Cable Probe

Liquids

2-Wire 4-20 mADC
Output

Bindicator GP 4 & Mark 4 Yo-Yo

Tank Top Unit with Weight & Retractable Cable

Solids, Liquids & Liquid / Solid Interface

4-20 mADC, RS-485(MODBUS) & Local Readout

Bindicator Phase Tracker

Tank Top Unit with Cable using Phase Difference Technology

Solids & Liquids -Ignores Dust, Vapors & Foam

4-20 mADC, RS-232, Modem, Relay & Local Readout

Bindicator SonoTracker

Tank Top Mounting Using Ultrasonic Technology

Solids & Liquid Level, Open Channel Flow and Differential Level

4-20 mADC, RS-485, Allen Bradley RIO, Profibus & Local Readout

Flow Transmitters

Aaliant

Insertion Flow Transmitters
In-Line Flow Transmitters
Sanitary In-Line Flow Transmitters

Target Meter

0.2 to 98,000 GPM Water
1 to 2,250,000 SCFM Air
3 to 6,000,000 PPH Steam

1/2″ to 60″ Pipe

15:1 Turndown Gas & Liquids
10:1 Turndown Steam

+/- 1% of Rate Accuracy

Barksdale

UQS7

Ultrasonic

0.1 to 45 GPM
Water-based Liquids

3/4″ to 1 1/4″ Pipe

250:1 Turndown

+/- 2.5% of Full Scale Accuracy

Bindicator

SonoTracker

Ultrasonic

Open Channel Flow
with Weir or Flume

2″ to 100″ Depth

10:1 Turndown

+/- 1% of Rate Accuracy

Kobold

DMI
PMG

Magetic Inductive

DMI: 0.7 to 320 GPM
PMG: 0.2 to 10,000 GPM
Liquids & Slurries

3/8″ to 12″ Pipe

12:1 to 30:1 Turndown Depending on Line Size

DMI: +/- 1.5% or 3% of Rate Accuracy
PMG: +/- 0.25% or 0.5% of Rate Accuracy

Dwyer

Series 641 Air Velocity

Heated Mass Flow Sensor

Up to 15,000 FPM Air

6″ to 36″ Insertion Probe

-40 to +212ºF

100 PSIG Maximum

-40 to +212ºF

Dwyer

Series AVU Air Velocity

Heat Loss Sensing Element

Up to 3,150 FPM Air

9″ Insertion Probe

32 to +122ºF

2 PSIG Maximum

+/-5% of Full Scale Accuracy

Dwyer

Series PF & PFS Air Velocity

Heated Mass Flow Sensor

PF: Up to 6,000 SFPM Air
PFS: Up to 15,000 SFPM Air

13″ Insertion Probe

-40 to +250ºF

150 PSIG Maximum

+/-1% of Full Scale Accuracy

Weber

Type 3205 vent-captor

Calorimetric principle

Up to 3,800 FPM Air

2″ Insertion Probe

-4 to +160ºF

145 PSIG Maximum

+/-5% of Full Scale Accuracy

Weber

Type 3302 vent-captor

Calorimetric principle

Up to 3800 FPM Air

8, 12, 18, 22 & 28 mm tubing

-4 to +160ºF

145 PSIG Maximum

+/-5% of Full Scale Accuracy

Weber

Type 4115 30 Smart Meterflow-captor

Calorimetric principle

Up to 6.5 FPS – Liquids

1.5″ to 24″ Pipe

32 to +176ºF

250 PSIG Maximum

+/-3% of Full Scale Accuracy

Weber

Types 4114 30 & 4115 30flow-captor

Calorimetric principle

Up to 6.5 FPS – Liquids

2.14″ or 2.4″ Insertion Probe

14 to +176ºF

435 PSIG Maximum

+/-5% of Full Scale Accuracy

Weber

Type 4311 30 flow-captor

Calorimetric principle

Up to 3.3 FPS – Liquids

8, 12, 18, 22 & 28 mm tubing

14 to +176ºF

435 PSIG Maximum

+/-5% of Full Scale Accuracy

Humidity and Oxygen Transmitters

EdgeTech

H-S Relative
Humidity Transmitter

Range: 10 to 95% RH (Operating: 40 to 160ºF)

Accuracy: +/- 3% RH
(30 to 80% RH)

Output: 0-10
VDC = %RH

Wall, Duct or Outside Air Mounting

EdgeTech

600 Relative Humidity & Temperature Transmitter

Ranges: 0 to 100% RH
-4 to +248ºF

Accuracies
+/- 2% RH (0 to 90% RH)
+/-0.6ºF (-4 to +122ºF)

Output(s): 4-20 mADC = %RH & Temperature

Wall, Duct or Remote Mounting

EdgeTech

650 Precision Relative Humidity & Temperature Transmitter

Ranges: 0 to 100% RH
-40 to +356ºF

Accuracies
+/- 1% RH (10 to 90% RH)
+/-0.36ºF (-4 to +140ºF)

Output(s): 4-20 mADC = %RH,
Dew Point or g/k
plus Temperature

Wall, Duct or Remote Mounting

EdgeTech

WBL-200 Wireless Relative Humidity & Temperature Data Logger

Ranges: 0 to 100% RH
-67 to +266ºF

Accuracies
+/- 2% RH (11 to 55% RH)
+/-1.8ºF @ 77ºF

20,000 Data Points On Board Data Logging. RS 232 & USB for Real Time Recording

Surface Mounting Enclosure

EdgeTech

HTPB Series Multi-Parameter Humidity & Temperature Probes

Ranges: 5 to 95% RH
-4 to +240ºF Temperature
-76 to +203ºF Dew Point
0-200 PSIA Pressure

Accuracy
+/- 1% RH (5 to 95% RH)

Outputs: RS 232 plus Three (3) 0-10 VDC = Selectable %RH, Dew Point, ppmv, ppmw, gr/lb, g/kg, Temperature or Pressure

Wall, Duct, 3/4″ Compression Fitting or Remote Mounting

EdgeTech

6740 Series Humidity Transmitter in Compressed Air

Range: -76 to +86ºF
Dew Point (Operating: 30″ Hg Vacuum to 0 to 725
PSIG Pressure)

Accuracy
+/- 3.6ºF @ 23ºF Dew Point

Outputs: 4-20 mADC = Selectable Dew Point or ppmv plus 2 optional alarms

1/2″ NPT
Process Connection

EdgeTech

Model 200 DewTrak Chilled Mirror Dew Point Transmitter

Range: -40 to +140ºF Dew Point (Operating: -40 to +162ºF Temperature; 1,000 PSIG Maximum Pressure)

Accuracy
+/- 1ºF Dew Point

Outputs: 4-20 mADC = Dew Point, %RH, Wet Bulb or Grains per Pound;Optional Temperature

Wall, Duct, 1 1/4″ NPT or Aspirator Mounting

EdgeTech

OxyTrans
Oxygen Transmitter

Oxygen Ranges: 0-100, 0-1,000
or 0-10,000 PPM 0-1 or 0-25% (Operating: -40 to +162ºF)

Accuracy:
+/- 2% FSD at Constant Temperature
+/- 5% FSD from 32 to 122ºF

Outputs: 4-20 mADC,
Alarm & Local Display

Compression Fittings with Flow-Through Measuring Cell